Set up consists of Process tank with 1) ON-OFF (Quick opening) Valve &
2) Linear Control Valve 3) Equal percentage Valve (Pneumatically controlled). In fluid circuit
controlled by manual air regulator. Complete set up on M S Powder coated structure.
VALVE DETAILS
VALVE TYPE : Globe type
LINE SIZE : 15 mm
VALVE LIFT : 28 mm
INLET Pr. : 4 Kg.
DIFF.. Pr. : 4 Kg Max.
CONTROL Pr. : 3-15 PSI
ACTUATION : Diaphragm Reverse actuated Close on supply failure
PNEUMATIC : ¼” N.P.T.
CONNECTION
BODY : CS SS-316
BONET TYPE : Standard Vertical Mount
Rotameter is incorporated in main stream to indicate the resultant flow of fluid.
Characteristics of valves can be studied by varying air pressure to valve.
Unit provides experimentation in-
1) Actuator Characteristics of ON-OFF Valve.
2) Actuator Characteristics of Linear Control Valve.
3) Actuator Characteristics of equal percentage Valve.
4) Study of stem positioning with fluid discharge for both valves.