(Micro controller based stand alone system with PC Interface & Software)
CONTROL : Micro controller based P I D controller with PC interface
SENSOR : 1) Differential Pr. transmitter with Orifice.
Magnetic float type level sensor for level sensing.
(RF capacitive with 4-20mA output optional.)
INDICATOR : Rotameter Flow Indicator 600 LPH (Optionally 1000 LPH)
3 ½ Digit digital display for Flow
MODE : System can operate in close loop or open loop
VALVE : Pneumatic Diaphragm type Linear OR Equal percentage with I-P
converter ½” line size CLOSE on Supply failure. Body CS – SS 316
FLUID SET UP : Centrifugal pump with electric motor, necessary pipelines & water
tanks. Manual valve / Bypass valve mounted on M S Powder
coated structure.
PC INTERFACE : RS-232 standard PC interface & Cable
SOFTWARE : Benix Pro User interactive GUI software with Graphical on line
display, Data storage & retrieval, Tabulation, Printing of tables &
graphs for off line analysis of data.
OPERATION MODE: STAND ALONE & THROUGH-PC both are available
POWER : 230 V AC Single Phase 5 A.
ACCESSORIES : All necessary accessories to perform experiment are provided with
the system. Unit can work without PC but provision for PC interface
& necessary software included in the cost. Electric supply, Water
supply & clean air supply 0f 0 -20 psi are required externally